| TYPE |
Insulation Resistance Meter |
| PHYSICAL SPECIFICATIONS |
19”W x 7H x 15”D, (48 cm x 17 cm x 38 cm)
Weight 24lbs (10.9 kg) |
| INPUT POWER |
110-120 Vac 50/60Hz or 220-240 Vac 50/60Hz, (selectable) |
RESISTANCE READING RANGE
(0°C to +30°C) |
100 K-ohm to 1 M-ohm ±20%
1 M-ohm to 1 T-ohm ±5%
1 T-ohm to 5 T-ohm ±20% , 5kV
100 K-ohm to 1 M-ohm ±20%
1 M-ohm to 100 G-ohm ±5%
100 G-ohm to 500 G-ohm ±5%, 500 V
1 M-ohm to 10 G-ohm ±5%, 50 V |
| TEST VOLTAGE |
Selectable from 50V to 5 kVdc, in 2 Vdc step |
OUTPUT VOLTAGE ACCURACY
(0°C to +30°C) |
±2% ±1v of selected voltage with load resistance >100 M |
| SHORT CIRCUIT CURRENT |
2mA max |
| CURRENT READING RANGE |
0.03 mA to 2 mA; Accuracy ±5% ±0.2 mA (0°C to +30°C) |
| CAPACITANCE READING RANGE |
0.01 μF to 10.0 μF (Test voltage >100V), Accuracy ±5% ±0.03 μF (0°C to +30°C) |
| VOLTAGE READING RANGE |
50-1250 Vac (rms) or dc, Accuracy ±5%, ±1V (0°C to +30°C) |
| CAPACITOR DISCHARGE |
<2 Sec/μF, Automatic at the end of test. |
| HUM REJECTION |
1mA per 1kv of Fast Voltage, 2mA rms maximum |
| BATTERIES |
Two 12V, 2.0 Ah Sealed, Lead Acid batteries. Battery life: typical 6 hrs, continuous testing.
The IRM-5000P can be used while charging |
| SAFETY |
UL Certified (UL 61010A-1), CAN/CSA Certified (C22.2 No. 1010.1-92) |
| ENVIRONMENT |
Operating: -10° to 50° C (15° to +122° F)
Storage: -30° C to 70° C (-22° to +158° F) |
| CABLES |
One 6’ cable set, One 15’ cable set, ground cable, power cord and cable bag |
| OPTIONS |
Transportation Case |
| WARRANTY |
One-Year on Parts and Labor |
|
 |