| TYPE |
Portable Current-Transformer Test Set |
| PHYSICAL DIMENSIONS |
16.8”W x 12.6”H x 12”L
(42.7 cm x 32 cm x 26.9 cm)
Weight: 48 lbs (21 kg) |
| INPUT POWER |
90-130 Vac or 200-240 Vac (user specified), 50 Hz/60 Hz |
| MEASUREMENT METHOD |
ANSI/IEEE C57.12.90 and ANSI/IEEE C57.13.1 |
| OUTPUT TEST VOLTAGE |
0-50 Vac @ 10A max, 0-250 Vac @ 10A max
0-500 Vac @ 5A max, 0-1500 Vac @ 1.2A max |
| VOLTAGE READING RANGE |
0 to 2,200 Vac, (Accuracy: ±1.0% of reading, ±1 volt) |
| CURRENT READING RANGE |
0 to 10A, (Accuracy: ±1.0% of reading, ±0.02A) |
| TURNS-RATIO RANGE |
0.8 to 999: 0.1%
1000 to 1999: 0.3%
2000 to 5000: 1% |
| PHASE ANGLE MEASUREMENT |
0 to 360 degree, Accuracy: ±1.0 degree |
| DISPLAY |
LCD Screen: 20 characters by 4 lines
Viewable in bright sunlight |
| PRINTER |
4.5-inch thermal printer |
| COMPUTER INTERFACE |
RS-232C Port (115k baud) and one USB Port |
| PC SOFTWARE |
Windows XP-based CT Analysis Program included with purchase price |
| TEST RECORD STORAGE |
Store 140 test records. Each test record may contain up to 10 sets of saturation, resistance and ratio data |
| TEST PLAN STORAGE |
Store 128 test plans. Each test plan stores 10 saturation test voltage and current settings |
| SAFETY |
Designed to meet UL 61010A-1 Certification and CAN/CSA C22.2 No. 1010.1-92 |
| ENVIRONMENT |
Operating: -10° to 50° C (15°F to +122° F)
Storage: -30° C to 70° C (-22°F to +158° F) |
| CABLES |
Two 20-ft X cables set
One 35-ft H cable set
Power cord
One cable-carrying duffel bag |
| WARRANTY |
One-Year parts & labor |
|
 |