| TYPE |
Portable relay test set |
| INPUT POWER |
100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz |
| PHYSICAL SPECIFICATIONS |
16.8”W x 12.6”H x 12”D (42.7 cm x 32.0 cm x 30.5 cm); Weight: 35 lbs (15.9 kg) |
| AMPERE METER INPUT RANGES |
Internal input range: 0 – 250 A; Accuracy: 2% of reading ± 10 mA, External AC input range: 0 – 6A; Accuracy: 1% of reading ± 10mA External DC input range: 0 – 6A; Accuracy: 0.5% of reading ±1 count Measurement Method: True RMS for AC |
| VOLT METER INPUT RANGE |
0 – 600.0V; AC accuracy: 1% of reading ±1 count; DC accuracy 0.5% of reading ±1 count Measurement Method: True RMS for AC |
| AUXILIARY POWER SUPPLIES |
24 Vdc @ 1 A, 124 Vdc @ 0.25 A, 240 Vac @ 0.125 A |
| SAFETY |
Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards |
| ENVIRONMENT |
Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚F to +158˚ F) |
| OPTIONS |
Transportation case |
| WARRANTY |
One year on parts and labor |
| AC Current Output |
| Range |
No-Load Voltage |
Load Voltage |
Load Current |
Load/Unload Times |
| 10 A |
90 Vac |
75 Vac |
10 A |
2 min / 15 min |
| 40 A |
25 Vac |
20 Vac |
40 A |
1 min / 15 min |
| 100 A |
10 Vac |
7.25 Vac |
100 A |
1 min / 15 min |
| 100 A |
10 Vac |
3 Vac |
250 A |
1 sec / 5 min |
|
| AC Voltage Output |
| Range |
No-Load Voltage |
Load Voltage |
Load Current |
Load/Unload Times |
| 250 Vac |
260 Vac |
240 Vac |
3 A |
10 min / 45 min |
|
| DC Voltage Output |
| Range |
No-Load Voltage |
Load Voltage |
Load Current |
Load/Unload Times |
| 300 Vdc |
300 Vac |
250 Vdc |
2 A |
10 min / 45 min |
|
| Maximum Current |
| 0.4 A |
| RFD-200 Timer Second Display In seconds and cycles (50/60 Hz programmable) |
| Range |
Resolution |
Accuracy |
| 0 to 9.999 sec |
1 ms |
± (1 ms + 0.01%) |
| 10.00 to 99.99 sec |
10 ms |
± (10 ms + 0.01%) |
| 100.0 to 999.999 sec |
100 ms |
± (100 ms + 0.01%) |
|
| Timer Cycles Display |
| Range |
Resolution |
Accuracy |
| 0 to 9.999 cycles |
0.1 cycle |
± (0.1 cycle + 0.01%) |
| 1,000 to 49,999 cycles / 50 Hz |
1 cycle |
± (1 cycle + 0.01%) |
|
|
The RFD-200 Digital Timer can be started or stopped in three different modes:
- Internal Trigger: Start timer with the presence or removal of RFD-200 voltage or current source.
- Dry Contact: Change of state of a dry contact input.
- Wet Contact: Change of state of a DC voltage input.
|
Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F). Last updated on February 16, 2009 |